ModEnc is currently in Maintenance Mode: Changes could occur at any given moment, without advance warning.
LaserFence: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
No edit summary |
||
Line 11: | Line 11: | ||
}} | }} | ||
Residual from Tiberian Sun. Can be set to 'yes' or 'no' and determines if this [[BuildingTypes]] acts as a Laser Fence. This means the structure acts like a wall and will automatically be created between two structures with {{f|LaserFencePost|yes|link}} set if they are present. The structure's SHP sequence must also be structured so that there are an equal number of frames for its enabled (supplied with power) and disabled (has no power) states. This is special case for the 'wall' logic, where this structure acts purely as the 'lengths' of the wall. | Residual from Tiberian Sun. Can be set to 'yes' or 'no' and determines if this [[BuildingTypes]] acts as a Laser Fence. This means the structure acts like a wall and will automatically be created between two structures with {{f|LaserFencePost|yes|link}} set if they are present. The structure's SHP sequence must also be structured so that there are an equal number of frames for its enabled (supplied with power) and disabled (has no power) states. This is special case for the 'wall' logic, where this structure acts purely as the 'lengths' of the wall. | ||
{{Bugs}} | |||
Due to Westwood's carelessness (after all, they did not intend to use this feature), this feature was damaged in YR1.001, the laserfencewall never turned on even if power on. | |||
*This bug has been fixed in Ares 0.1. |
Latest revision as of 18:41, 6 October 2024
Flag: | LaserFence |
File(s): | rules(md).ini |
Values: | Boolean values: yes or no, true or false, 1 or 0 |
Default: | no |
Applicable to: | BuildingTypes |
Residual from Tiberian Sun. Can be set to 'yes' or 'no' and determines if this BuildingTypes acts as a Laser Fence. This means the structure acts like a wall and will automatically be created between two structures with LaserFencePost=yes set if they are present. The structure's SHP sequence must also be structured so that there are an equal number of frames for its enabled (supplied with power) and disabled (has no power) states. This is special case for the 'wall' logic, where this structure acts purely as the 'lengths' of the wall.
Bugs/Side-Effects/Unexpected Limitations
Due to Westwood's carelessness (after all, they did not intend to use this feature), this feature was damaged in YR1.001, the laserfencewall never turned on even if power on.
- This bug has been fixed in Ares 0.1.